Product documentation — installation, licensing, and integration guides.
Domains
Power grid and controls

Power grid and controls: Domain Specification

Linear analysis bench · ship and base power · EMTP-adjacent V&V · Domain / program lane

Product titlePower grid and controls (domain)Document statusExternal draft 1.0
Prepared byResonix Labs (USA), Inc.Date issued20 October 2026
Domain overview
Program lane
Typical programs
Power, ship-service, and grid-adjacent programs need transfer functions, margins, and linearized network behavior without running a nonlinear ODE integrator on the wrong problem class. SolvLRDE is the primary fit on the analysis bench; stiff, noisy coupled dynamics on ships or vehicles still route to SolvSRK. Resonix does not operate utilities or ship plants.
Ship and base power / network linearized models; Integrated air and missile defense linearized chains; Grid and SCADA-adjacent linear V&V (customer models); Control-law and avionics stability studies
Eval path
Scenario
30-day trial on representative LTI models vs incumbent toolbox; confirm problem stays linear before embed.
Cert wants linear analysis; the team only has time-steppers Reviewers ask for margins on a linearized chain. Engineers burn cluster time on nonlinear time-stepping because it is the only tool licensed today. SolvLRDE addresses LTI work directly; route stiff vehicle or plant transients to SolvSRK.
Resonix boundary
We license libraries your engineers embed. We do not operate your radar, sonar, fusion center, C2, or autonomy stack.
Where it fits

Linearized plant / network model→SolvLRDE (direct LTI analysis)→cert artifacts, margins, frequency response→Deterministic replay on control hot paths: SolvNum

Stack (typical)

  • Ship and base power / network linearized models
  • Integrated air and missile defense linearized chains
  • Grid and SCADA-adjacent linear V&V (customer models)
  • Control-law and avionics stability studies
Capabilities

Deliverables Resonix licenses in this domain (library behavior and artifacts). See product technical sheets for full spec grids.

CodeCapabilityDeliverableProduct
C1Linear plant / network analysisDirect LTI kernel for margins, TF, and cert-style artifacts.SolvLRDE (Primary)
C2Nonlinear coupled transientsShip or vehicle dynamics when stiffness and noise dominate.SolvSRK (Primary)
C3Control-path replay parityDeterministic bounded hot paths for qual.SolvNum (Supporting)
C4Integrator class routingSeparate linear bench from nonlinear IVP before lock-in.SolvScout / SolvTune (Supporting)
Product spec snapshot (this domain)

Quantitative lines a practitioner in this lane would budget or eval; not a repeat of capabilities. Lab metrics are labeled; end-to-end proof is on customer tapes.

SolvLRDE

  • Why embed: SolvLRDE integrates linearized radar, controls, and network models in one analysis step · transfer functions, margins, and cert-style LTI artifacts without time-stepping a nonlinear integrator on the wrong problem class (not a transient IVP solver).
  • Why try now: 30-day self-serve trial on representative LTI models vs incumbent toolbox; confirm the problem stays linear, then embed the same kernel in your V&V workflow.
  • In this lane: Radar, controls, power, and network linear analysis without time-stepping.
  • Integration: One-step LTI kernel on linearized chains · margins, transfer functions, and cert-style artifacts without time-stepping a nonlinear integrator.
  • Lab: Direct linear analysis vs incumbent toolbox on representative LTI models (30-day self-serve trial path).

SolvSRK

  • Why embed: SolvSRK is a stiffness-aware hybrid IVP integrator that keeps noisy, coupled plant and between-frame propagation completing when standard BDF/RK arms stall · drop it into your existing dynamics call path (not a planner, SLAM, or vision product).
  • Why try now: 30-day side-by-side on your RHS, tolerances, and noise coupling; pass/fail on survival, wall time, and error vs incumbent. Run SolvScout/SolvTune first to surface dead zones before lock-in.
  • In this lane: Nonlinear ship or vehicle dynamics when stiffness and noise couple.
  • Integration: SciPy-shaped IVP API in plant sim, planning/control loops, and tracking predict steps; you own RHS, tolerances, and noise coupling.
  • Lab IVP (not mission KPI): vs standard BDF on reference noise battery, 0% incumbent survival at σ≥0.1; SolvSRK 100% through σ=1.0; 100% survival on four stiff classes (30 seeds each).

SolvNum

  • Why embed: SolvNum is a deterministic arithmetic substrate on the hot path you choose · same inputs produce bit-identical outputs across laptop, HIL, and tactical processors for qual and anomaly replay (not a replacement for your fusion or control logic).
  • Why try now: 3-6 month subsystem pilot on a bounded path you define; pass/fail bit-identical output across your qual hardware matrix.
  • In this lane: Deterministic replay on bounded control or fusion paths.
  • Integration: Deterministic substrate on a bounded hot path you define (fusion replay, control qual); pairs with SolvSRK-Edge when HIL and field must match.

SolvScout / SolvTune

  • Why embed: SolvScout and SolvTune fingerprint your dynamics locally and rank honest integrator routing · including when SolvSRK is not the fit · before you freeze HIL or flight software (not an integrator themselves).
  • Why try now: Free local portal wheel; customer RHS never leaves your network. Use the 443-problem corpus readout, then scope a 30-day SolvSRK side-by-side only when Tune recommends it.
  • In this lane: Route linear vs nonlinear integrator before program lock.
  • Integration: Pre-production local wheel; fingerprint representative models before HIL or flight-software freeze; archive Scout/Tune report with SBOM when SRK is selected.